Put the proven electronic technology to work in your fields-cutting costs and increasing productivity- with the compact, easy-to-operate CCS100 Custom Control System. Once you program the system for your required gallons per acre application rate, the CCS100 gives you fully automatic control as your ground speed changes. The CCS100 system is designed for maximum precision and minimum maintenance.
Formula:
- GPA x MPH x W (ft.) x .00202 = GPM
Example: (20) x (7) x (32) x .00202 = 9.05 GPM
In this example, a flow of 9.05 GPM shows that a 20 GPM system is adequate.